Component DisplayInstruction (Block)

The DisplayInstruction component block is used to convey instructions on how a reserved order is to be handled in terms of when and how much of the order quantity is to be displayed to the market.

Added in protocol FIX.4.4

See in: FIX.5.0SP1, FIX.5.0SP2, FIX.5.0SP2 EP240.

Field or Component Name Description Is Required Added Is Deprecated
1138 DisplayQty FIX.4.4
1082 SecondaryDisplayQty FIX.4.4
1083 DisplayWhen FIX.4.4
1084 DisplayMethod FIX.4.4
1085 DisplayLowQty Required when DisplayMethod = 3 FIX.4.4
1086 DisplayHighQty Required when DisplayMethod = 3 FIX.4.4
1087 DisplayMinIncr Can be used to specify larger increments than the standard increment provided by the market. Optionally used when DisplayMethod = 3 FIX.4.4
1088 RefreshQty Required when DisplayMethod = 2 FIX.4.4